  "id": "scd40",
  "name": "SCD40 CO2 sensor",
  "category": "sensor",
  "measures": [
    "co2",
    "temperature",
    "humidity"
  ],
  "pins": [
    {
      "name": "VIN",
      "role": "power"
    },
    {
      "name": "GND",
      "role": "ground"
    },
    {
      "name": "SCL",
      "role": "i2c_scl"
    },
    {
      "name": "SDA",
      "role": "i2c_sda"
    }
  ],
  "bus": "i2c",
  "addresses": [
    "0x62"
  ],
  "voltage": "3.3-5",
  "pullupsOnBoard": true,
  "model": {
    "shape": "breakout",
    "size": [
      18,
      18,
      7
    ],
    "color": "#1A1A1A"
  },
  "keywords": [
    "scd40",
    "scd41",
    "sensirion",
    "co2",
    "carbon dioxide",
    "anidride carbonica",
    "qualità aria"
  ],
  "sources": [
    {
      "title": "Sensirion SCD4x datasheet",
      "section": "I2C address 0x62; supply 2.4 to 5.5 V"
    }
  ]
}